{"product_id":"wago-2006-1413","title":"Wago - 2006-1401","description":"\u003cp\u003eWAGO component - equivalent to 20061401\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4066966595772\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2006-1401\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 20061401\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e 4-conductor through terminal block; 6mm2; suitable for Ex e II applications; side and center marking; for DIN-rail 35 x 15 and 35 x 7.5; Push-in CAGE CLAMP; 6mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60947-7-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 800V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 8kV|Electrical data - Ratings per IEC\/EN - Rated current -- 41A|Electrical data - Ratings per IEC\/EN - Current at conductor cross-section (max.)mm2 -- 53A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL - Approvals per -- UL 1059|Electrical data - Ratings per UL - Rated voltage UL (Use Group B) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group B) -- 50A|Electrical data - Ratings per UL - Rated voltage UL (Use Group C) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group C) -- 50A|Electrical data - Ratings per CSA - Approvals per -- CSA 22.2 No 158|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group B) -- 600V|Electrical data - Ratings per CSA - Rated current CSA (Use Group B) -- 50A|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group C) -- 600V|Electrical data - Ratings per CSA - Rated current CSA (Use Group C) -- 50A|Electrical data - Ex information - Ratings per -- ATEX PTB 05 ATEX 1030 U \/ IECEx PTB 05.0014U (Ex eb IIC Gb)|Electrical data - Ex information - Rated voltage EN (Ex e II) -- 550V|Electrical data - Ex information - Rated current (Ex e II) -- 36A|Electrical data - Ex information - Rated current (Ex e II) with jumper -- 33A|Electrical data - Power Loss - Rated current I\u003csub\u003eN\u003c\/sub\u003e for specified power loss -- 41A|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 1|Connection data - Number of levels -- 1|Connection data - Number of jumper slots -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool|Connection data - Connection 1 - Connectable conductor materials -- Copper|Connection data - Connection 1 - Nominal cross-section -- 6mm2|Connection data - Connection 1 - Solid conductor -- 0.5...10mm2 \/ 20...8 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 2.5...10mm2 \/ 14...8 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...10mm2 \/ 20...8 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...10mm2 \/ 20...8 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.5...6mm2 \/ 20...10 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 2.5...6mm2 \/ 16...10 AWG|Connection data - Connection 1 - Note (conductor cross-section) -- Depending on the conductor characteristic; a conductor with a smaller cross-section can also be inserted via push-in termination.|Connection data - Connection 1 - Strip length -- 13...15mm \/ 0.51...0.59\"|Connection data - Connection 1 - Wiring direction -- Front-entry wiring|Physical data - Width -- 7.5mm \/ 0.295\"|Physical data - Height -- 89.3mm \/ 3.516\"|Physical data - Depth from upper-edge of DIN-rail -- 32.9mm \/ 1.295\"|Physical data - Depth -- 39.5mm \/ 1.555\"|Mechanical data - Mounting type -- DIN-35 rail|Mechanical data - Marking level -- Center\/side marking|Material data - Color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Fire load -- 0.284MJ|Material data - Weight -- 16.3g|Environmental requirements - Processing temperature -- -35...+85°C|Environmental requirements - Continuous operating temperature -- -60...+105°C|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 25 pcs|Commercial data - Packaging type -- Box|Commercial data - Country of origin -- DE|Commercial data - GTIN -- 4066966595772|Commercial data - Customs tariff number -- 85369010000|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Terminal blocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85369010000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4066966595772\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 25 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 10 mm² \/ 20 … 8 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 2.5 … 6 mm² \/ 16 … 10 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.5 … 6 mm² \/ 20 … 10 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 6 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Note (conductor cross-section):\u003c\/strong\u003e Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 10 mm² \/ 20 … 8 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 2.5 … 10 mm² \/ 14 … 8 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 10 mm² \/ 20 … 8 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 13 … 15 mm \/ 0.51 … 0.59 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Wiring direction:\u003c\/strong\u003e Front-entry wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of jumper slots:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Rated current (Ex e II):\u003c\/strong\u003e 36A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Rated current (Ex e II) with jumper:\u003c\/strong\u003e 33A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Rated voltage EN (Ex e II):\u003c\/strong\u003e 550V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Ratings per:\u003c\/strong\u003e ATEX: PTB 05 ATEX 1030 U \/ IECEx: PTB 05.0014U (Ex eb IIC Gb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Reference hazardous areas:\u003c\/strong\u003e See application instructions in section “Knowledge and\u003cbr\u003e\t\t\t\t\tDownloads – Documentation – Additional Information: Technical Section; Technical Explications”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Rated current I\u003csub\u003eN\u003c\/sub\u003e for specified power loss:\u003c\/strong\u003e 41A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Approvals per:\u003c\/strong\u003e CSA 22.2 No 158\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group B):\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group C):\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group B):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group C):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Current at conductor cross-section (max.) mm²:\u003c\/strong\u003e 53A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 800V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 41A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 8kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60947-7-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Approvals per:\u003c\/strong\u003e UL 1059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group B):\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group C):\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group B):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group C):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -60 … +105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.284MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 16.3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking level:\u003c\/strong\u003e Center\/side marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.5 mm \/ 1.555 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 32.9 mm \/ 1.295 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 89.3 mm \/ 3.516 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 mm \/ 0.295 inches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695002468489,"sku":"60564576","price":6.25,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2006-1413","provider":"US Automation Controls","version":"1.0","type":"link"}