{"product_id":"wago-2002-1712","title":"Wago - 2002-1711","description":"\u003cp\u003eFeed-through\/thru terminal block with 1-deck\/level + fused-disconnect (lever type; 5x20mm) + built-in end plate (terminal is closed on both sides) + side\/lateral and center marking slots - Suitable for Ex e II applications - WAGO (2002 TOPJOB S series) - Gray - 1 feed-through pole (1P) \/ 3-wires (1 push-in + 2 push-in) (1+2) - 2.5mm2 nominal cross-section - for 0.25mm2...4mm2 \/ for #22AWG...#12AWG - Rated current 6.3A - with Push-in CAGE CLAMP spring connections - DIN-35 rail (35 x 15 \/ 35 x 7.5) mounting (6.2mm width) - equivalent to 20021711\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Feed-through\/thru terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e 1-deck\/level|fused-disconnect (lever type; 5x20mm)|built-in end plate (terminal is closed on both sides)|side\/lateral and center marking slots|2 jumper slots|Suitable for Ex e II applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1 feed-through pole (1P)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e (IEC) 6.3A|(UL) 10A|(CSA) 10A|(Ex e II) 6.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection capacity:\u003c\/strong\u003e 3-wires (1 push-in + 2 push-in) (1+2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e (IEC) 250V|(UL) 250V|(CSA) 250V|(Ex e II) 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage (Uimp):\u003c\/strong\u003e (IEC) 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-section:\u003c\/strong\u003e for 0.25mm2...4mm2 fine stranded or solid conductors|for 0.25mm2...2.5mm2 fine stranded conductors with insulated ferrule|for 1mm2...2.5mm2 fine stranded conductors with ferrule; push-in termination|for 0.75mm2...4mm2 solid conductors; push-in termination|for #22AWG...#12AWG fine stranded or solid conductors|for #22AWG...#14AWG fine stranded conductors with insulated ferrule|for #18AWG...#14AWG fine stranded conductors with ferrule; push-in termination|for #18AWG...#12AWG solid conductors; push-in termination|2.5mm2 nominal cross-section\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail (35 x 15 \/ 35 x 7.5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H76.8mm x W6.2mm x D57.6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 6.2mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polyamide (PA) 66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821707608\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC000899\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-14-11-16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85369095000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2002-1711\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 20021711\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143873352\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL 7941|- CSA - DEKRA Certification B.V. - C22.2 No. 158 - certificate 1536069|- KEMA\/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-124163|- UL - Underwriters Laboratories Inc. - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- ATEX-Attestation of Conformity - WAGO GmbH \u0026amp; Co. KG|- ATEX-Attestation of Conformity - WAGO GmbH \u0026amp; Co. KG|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- Railway - WAGO GmbH \u0026amp; Co. KG - certificate Railway Ready|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - EN 60947 - certificate 20-HG1941090-PDA|- DNV GL - Det Norske Veritas Germanischer Lloyd - certificate TAE00001V2|Approvals for hazardous areas|- AEx - Underwriters Laboratories Inc. - UL 60079 - certificate E185892 (AEx eb IIC resp. Ex eb IIC)|- ATEX - KIWA Netherlands B.V. - EN 60079 - certificate KIWA 17ATEX0030 U|- CCC - CNEX - GB\/T 3836.3 - certificate 2020312313000180 (Ex ec IIC Gc)|- IECEx - KIWA Netherlands B.V. - EN 60079 - certificate IECEx KIWA 17.0014U (Ex ec IIC Gc)|RoHS compliant|material group I|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Feed-through\/thru terminal block - 1-deck\/level - WAGO (TOPJOB S series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85369095000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-14-11-16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-14-11-16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC000899\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC000899\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821707608\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 22 (TOPJOB S)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 4 mm² \/ 22 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1 … 2.5 mm² \/ 18 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 2.5 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Note (conductor cross-section):\u003c\/strong\u003e Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 4 mm² \/ 22 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 4 mm² \/ 18 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 10 … 12 mm \/ 0.39 … 0.47 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Wiring direction:\u003c\/strong\u003e Front-entry wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of jumper slots:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Rated current (Ex e II):\u003c\/strong\u003e 6.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Rated voltage EN (Ex e II):\u003c\/strong\u003e 275V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Ratings per:\u003c\/strong\u003e ATEX: KIWA 17 ATEX 0030 U \/ IECEx: KIWA 17.0014U (Ex ec IIC Gc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx information - Reference hazardous areas:\u003c\/strong\u003e See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Fuse receptacle:\u003c\/strong\u003e pivoting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Fuse type:\u003c\/strong\u003e Cylindrical fuse; 5 x 20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Power loss (max.) P\u003csub\u003el (max.)\u003c\/sub\u003e (note):\u003c\/strong\u003e When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3\/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Power loss P\u003csub\u003el\u003c\/sub\u003e max. overload and short-circuit protection (group arrangement):\u003c\/strong\u003e 1.6W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Power loss P\u003csub\u003el\u003c\/sub\u003e max. overload and short-circuit protection (individual arrangement):\u003c\/strong\u003e 1.6W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Power loss P\u003csub\u003el\u003c\/sub\u003e max. short-circuit protection (group arrangement):\u003c\/strong\u003e 2.5W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Power loss P\u003csub\u003el\u003c\/sub\u003e max. short-circuit protection (individual arrangement):\u003c\/strong\u003e 2.5W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Approvals per:\u003c\/strong\u003e CSA 22.2 No 158\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group B):\u003c\/strong\u003e 6.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group C):\u003c\/strong\u003e 6.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group C):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 6.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60947-7-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Ratings (note):\u003c\/strong\u003e Electrical ratings are given by the fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Approvals per:\u003c\/strong\u003e UL 1059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group B):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group C):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group D):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group B):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group C):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group D):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -60 … +105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Acceleration:\u003c\/strong\u003e 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Frequency:\u003c\/strong\u003e f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz|f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Function test with noise-like vibration:\u003c\/strong\u003e Test passed according to Section 8 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Number of shocks per axis:\u003c\/strong\u003e 3 pos. und 3 neg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock duration:\u003c\/strong\u003e 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock form:\u003c\/strong\u003e Half sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock test:\u003c\/strong\u003e Test passed according to Section 10 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration:\u003c\/strong\u003e Test passed according to Section 9 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Spectrum\/Installation location:\u003c\/strong\u003e Service life test, Category 1, Class A\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test directions:\u003c\/strong\u003e X, Y and Z axes|X, Y and Z axes|X, Y and Z axes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test duration per axis:\u003c\/strong\u003e 10 min.|5 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test procedure \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock equipment – \u003cbr\u003eShock and vibration tests:\u003c\/strong\u003e DIN EN 61373 (VDE 0115-0106):2011-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test specification \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock – \u003cbr\u003eElectronic equipment:\u003c\/strong\u003e DIN EN 50155 (VDE 0115-200):2022-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.375MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 14.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking level:\u003c\/strong\u003e Center\/side marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 57.6 mm \/ 2.268 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 76.8 mm \/ 3.024 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6.2 mm \/ 0.244 inches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47696178118793,"sku":"60401903","price":11.19,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2002-1712","provider":"US Automation Controls","version":"1.0","type":"link"}