Feed-through/thru terminal block with 1-deck/level + fused-disconnect (lever type; 5x20mm) + built-in end plate (terminal is closed on both sides) + side/lateral and center marking slots - Suitable for Ex e II applications - WAGO (2002 TOPJOB S series) - Gray - 1 feed-through pole (1P) / 3-wires (1 push-in + 2 push-in) (1+2) - 2.5mm2 nominal cross-section - for 0.25mm2...4mm2 / for #22AWG...#12AWG - Rated current 6.3A - with Push-in CAGE CLAMP spring connections - DIN-35 rail (35 x 15 / 35 x 7.5) mounting (6.2mm width) - equivalent to 20021711

Specifications

  • Primary brand: WAGO
  • Functions: Feed-through/thru terminal block
  • Design: 1-deck/level|fused-disconnect (lever type; 5x20mm)|built-in end plate (terminal is closed on both sides)|side/lateral and center marking slots|2 jumper slots|Suitable for Ex e II applications
  • Poles: 1 feed-through pole (1P)
  • Temperature: Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C
  • Rated current: (IEC) 6.3A|(UL) 10A|(CSA) 10A|(Ex e II) 6.3A
  • Color: Gray
  • Connection capacity: 3-wires (1 push-in + 2 push-in) (1+2)
  • Rated operating voltage (Ue): (IEC) 250V|(UL) 250V|(CSA) 250V|(Ex e II) 250V
  • Rated impulse voltage (Uimp): (IEC) 6kV
  • Connection type: Push-in CAGE CLAMP spring connections
  • Cross-section: for 0.25mm2...4mm2 fine stranded or solid conductors|for 0.25mm2...2.5mm2 fine stranded conductors with insulated ferrule|for 1mm2...2.5mm2 fine stranded conductors with ferrule; push-in termination|for 0.75mm2...4mm2 solid conductors; push-in termination|for #22AWG...#12AWG fine stranded or solid conductors|for #22AWG...#14AWG fine stranded conductors with insulated ferrule|for #18AWG...#14AWG fine stranded conductors with ferrule; push-in termination|for #18AWG...#12AWG solid conductors; push-in termination|2.5mm2 nominal cross-section
  • Mounting mode: DIN-35 rail (35 x 15 / 35 x 7.5)
  • Dimensions: H76.8mm x W6.2mm x D57.6mm
  • Net Width (mm): 6.2mm
  • Material: Polyamide (PA) 66
  • GTIN code: 4050821707608
  • ETIM code: EC000899
  • eClass code: 27-14-11-16
  • Customs Tariff Number: 85369095000
  • Order code / Manufacturer SKU: 2002-1711
  • Manufacturer product status: Commercialized
  • Equivalent to: 20021711
  • EAN code: 4055143873352
  • Compliant with standard(s): General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL 7941|- CSA - DEKRA Certification B.V. - C22.2 No. 158 - certificate 1536069|- KEMA/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-124163|- UL - Underwriters Laboratories Inc. - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- ATEX-Attestation of Conformity - WAGO GmbH & Co. KG|- ATEX-Attestation of Conformity - WAGO GmbH & Co. KG|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- Railway - WAGO GmbH & Co. KG - certificate Railway Ready|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - EN 60947 - certificate 20-HG1941090-PDA|- DNV GL - Det Norske Veritas Germanischer Lloyd - certificate TAE00001V2|Approvals for hazardous areas|- AEx - Underwriters Laboratories Inc. - UL 60079 - certificate E185892 (AEx eb IIC resp. Ex eb IIC)|- ATEX - KIWA Netherlands B.V. - EN 60079 - certificate KIWA 17ATEX0030 U|- CCC - CNEX - GB/T 3836.3 - certificate 2020312313000180 (Ex ec IIC Gc)|- IECEx - KIWA Netherlands B.V. - EN 60079 - certificate IECEx KIWA 17.0014U (Ex ec IIC Gc)|RoHS compliant|material group I|V-0 flammability rating
  • Location of origin: China
  • Level 1 category: Electrical components
  • Level 2 category: Terminal blocks
  • Product title: Feed-through/thru terminal block - 1-deck/level - WAGO (TOPJOB S series)

Commercial data

  • Country of origin: CN
  • Customs tariff number: 85369095000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-16
  • eCl@ss 9.0: 27-14-11-16
  • ETIM 8.0: EC000899
  • ETIM 9.0: EC000899
  • GTIN: 4050821707608
  • Packaging type: box
  • Product Group: 22 (TOPJOB S)
  • PU (SPU): 50 pcs

Connection data

  • Clamping units: 3
  • Connection 1 - Actuation type: Operating tool
  • Connection 1 - Connectable conductor materials: Copper
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.25 … 4 mm² / 22 … 12 AWG
  • Connection 1 - Fine-stranded conductor; with ferrule; push-in termination: 1 … 2.5 mm² / 18 … 14 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.25 … 2.5 mm² / 22 … 14 AWG
  • Connection 1 - Nominal cross-section: 2.5 mm²
  • Connection 1 - Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 - Solid conductor: 0.25 … 4 mm² / 22 … 12 AWG
  • Connection 1 - Solid conductor; push-in termination: 0.75 … 4 mm² / 18 … 12 AWG
  • Connection 1 - Strip length: 10 … 12 mm / 0.39 … 0.47 inches
  • Connection 1 - Wiring direction: Front-entry wiring
  • Number of jumper slots: 2
  • Number of levels: 1
  • Total number of potentials: 1

Electrical data

  • Ex information - Rated current (Ex e II): 6.3A
  • Ex information - Rated voltage EN (Ex e II): 275V
  • Ex information - Ratings per: ATEX: KIWA 17 ATEX 0030 U / IECEx: KIWA 17.0014U (Ex ec IIC Gc)
  • Ex information - Reference hazardous areas: See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
  • General information - Fuse receptacle: pivoting
  • General information - Fuse type: Cylindrical fuse; 5 x 20 mm
  • Power Loss - Power loss (max.) Pl (max.) (note): When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
  • Power Loss - Power loss Pl max. overload and short-circuit protection (group arrangement): 1.6W
  • Power Loss - Power loss Pl max. overload and short-circuit protection (individual arrangement): 1.6W
  • Power Loss - Power loss Pl max. short-circuit protection (group arrangement): 2.5W
  • Power Loss - Power loss Pl max. short-circuit protection (individual arrangement): 2.5W
  • Ratings per CSA - Approvals per: CSA 22.2 No 158
  • Ratings per CSA - Rated current CSA (Use Group B): 6.3A
  • Ratings per CSA - Rated current CSA (Use Group C): 6.3A
  • Ratings per CSA - Rated voltage CSA (Use Group C): 250V
  • Ratings per IEC/EN - Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • Ratings per IEC/EN - Nominal voltage (III/3): 250V
  • Ratings per IEC/EN - Rated current: 6.3A
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 6kV
  • Ratings per IEC/EN - Ratings per: IEC/EN 60947-7-3
  • Ratings per IEC/EN – Notes - Ratings (note): Electrical ratings are given by the fuse.
  • Ratings per UL - Approvals per: UL 1059
  • Ratings per UL - Rated current UL (Use Group B): 10A
  • Ratings per UL - Rated current UL (Use Group C): 10A
  • Ratings per UL - Rated current UL (Use Group D): 10A
  • Ratings per UL - Rated voltage UL (Use Group B): 250V
  • Ratings per UL - Rated voltage UL (Use Group C): 250V
  • Ratings per UL - Rated voltage UL (Use Group D): 250V

Environmental Product Compliance

  • RoHS Compliance Status: Compliant,No Exemption

Environmental requirements

  • Continuous operating temperature: -60 … +105 °C
  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
  • Processing temperature: -35 … +85 °C

Material data

Mechanical data

  • Marking level: Center/side marking
  • Mounting type: DIN-35 rail

Physical data

  • Depth from upper-edge of DIN-rail: 57.6 mm / 2.268 inches
  • Height: 76.8 mm / 3.024 inches
  • Width: 6.2 mm / 0.244 inches