{"product_id":"wago-2000-5457","title":"Wago - 2000-5457","description":"\u003cp\u003eSensr. suppl. terminal block with 4-decks\/levels (quadruple-deck) + ground contact + side\/lateral and center marking slots - for PNP-(high-side) switching sensr. - WAGO (2000 TOPJOB S series) - Orange - 4-conductors \/ 9-wires (9 push-in) - 1mm2 nominal cross-section - for 0.14mm2...1.5mm2 \/ for #24AWG...#16AWG - Rated current 28A - with Push-in CAGE CLAMP spring connections - DIN-35 rail mounting (7mm width) - equivalent to 20005457\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Sensr. suppl. terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e 4-decks\/levels (quadruple-deck)|ground contact|side\/lateral and center marking slots|colored wire entry|3 jumper slots|for PNP-(high-side) switching sensr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 4-conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e (IEC) 28A|(UL) 15A|(CSA) 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection capacity:\u003c\/strong\u003e 9-wires (9 push-in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e (UL) 24V|(CSA) 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-section:\u003c\/strong\u003e for 0.14mm2...1.5mm2 fine stranded or solid conductors|for 0.14mm2...0.75mm2 fine stranded conductors with insulated ferrule|for 0.5mm2...0.75mm2 fine stranded conductors with ferrule; push-in termination|for 0.5mm2...1.5mm2 solid conductors; push-in termination|for #24AWG...#16AWG fine stranded or solid conductors|for #24AWG...#18AWG fine stranded conductors with insulated ferrule|for #20AWG...#18AWG fine stranded conductors with ferrule; push-in termination|for #20AWG...#16AWG solid conductors; push-in termination|1mm2 nominal cross-section\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H97.3mm x W7mm x D49.4mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 7mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polyamide (PA) 66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC000900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85369010000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143504591\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-14-11-28\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2000-5457\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 20005457\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143504591\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL 7962|- CSA - DEKRA Certification B.V. - C22.2 - certificate 2130762|- KEMA\/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-125928|- UL - Underwriters Laboratories Inc. - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- Railway - WAGO GmbH \u0026amp; Co. KG - certificate Railway Ready|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|RoHS compliant|material group I|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Sensr. suppl. terminal block - 4-decks\/levels (quadruple-deck) - WAGO (TOPJOB S series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85369010000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-14-11-28\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-14-11-28\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC000900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC000900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143504591\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 15 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connectable conductor materials:\u003c\/strong\u003e Copper|Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.14 … 1.5 mm² \/ 24 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.5 … 0.75 mm² \/ 20 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.14 … 0.75 mm² \/ 24 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Note (conductor cross-section):\u003c\/strong\u003e Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.14 … 1.5 mm² \/ 24 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.5 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 … 11 mm \/ 0.35 … 0.43 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Wiring direction:\u003c\/strong\u003e Front-entry wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 2 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 4 mm² \/ 22 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 2 - Solid conductor:\u003c\/strong\u003e 0.25 … 4 mm² \/ 22 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 2 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.25 … 4 mm² \/ 22 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of jumper slots:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Power loss, per pole (potential):\u003c\/strong\u003e 1.043W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Rated current I\u003csub\u003eN\u003c\/sub\u003e for specified power loss:\u003c\/strong\u003e 28A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss - Resistance value for specified, current-dependent power loss:\u003c\/strong\u003e 0.001Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Approvals per:\u003c\/strong\u003e CSA 22.2 No 158\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group C):\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group C):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 28A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60947-7-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Approvals per:\u003c\/strong\u003e UL 1059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group B):\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group D):\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group B):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group D):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -60 … +105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Acceleration:\u003c\/strong\u003e 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Frequency:\u003c\/strong\u003e f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz|f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Function test with noise-like vibration:\u003c\/strong\u003e Test passed according to Section 8 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Number of shocks per axis:\u003c\/strong\u003e 3 pos. und 3 neg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock duration:\u003c\/strong\u003e 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock form:\u003c\/strong\u003e Half sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock test:\u003c\/strong\u003e Test passed according to Section 10 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration:\u003c\/strong\u003e Test passed according to Section 9 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Spectrum\/Installation location:\u003c\/strong\u003e Service life test, Category 1, Class A\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test directions:\u003c\/strong\u003e X, Y and Z axes|X, Y and Z axes|X, Y and Z axes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test duration per axis:\u003c\/strong\u003e 10 min.|5 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test procedure \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock equipment – \u003cbr\u003eShock and vibration tests:\u003c\/strong\u003e DIN EN 61373 (VDE 0115-0106):2011-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test specification \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock – \u003cbr\u003eElectronic equipment:\u003c\/strong\u003e DIN EN 50155 (VDE 0115-200):2022-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.353MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 23g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking level:\u003c\/strong\u003e Center\/side marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail|DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 49.4 mm \/ 1.945 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 97.3 mm \/ 3.831 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7 mm \/ 0.276 inches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47696209903753,"sku":"60310320","price":21.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000e00032665000300b6_de_2000-0200002200020d93000100b6-de_ca8cac11-2359-41f3-8033-9503525d18be.jpg?v=1786992371","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2000-5457","provider":"US Automation Controls","version":"1.0","type":"link"}