Neutral-through terminal block with marker carrier + 2-decks/levels (double-deck) + internal commoning + side/lateral and center marking slots - Suitable for Ex e II / Ex I applications - with "N" marking - WAGO (2000 TOPJOB S series) - Blue - Neutral-through pole (N) / 2 x 2-wires (2 push-in + 2 push-in) (2+2) - 1mm2 nominal cross-section - for 0.14mm2...1.5mm2 / for #24AWG...#16AWG - Rated current 13.5A / 16A - with Push-in CAGE CLAMP spring connections - DIN-35 rail (35 x 15 / 35 x 7.5) mounting (3.5mm width) - equivalent to 20002239

Specifications

  • Primary brand: WAGO
  • Functions: Neutral-through terminal block
  • Design: marker carrier|2-decks/levels (double-deck)|internal commoning|side/lateral and center marking slots|violet wire entry|3 jumper slots|Suitable for Ex e II / Ex I applications
  • Poles: Neutral-through pole (N)
  • Temperature: Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C
  • Rated current: (IEC) 13.5A|(IEC) 16A|(UL) 10A|(Ex e II) 13A|(Ex e II with jumper) 12A
  • Color: Blue
  • Connection capacity: 2 x 2-wires (2 push-in + 2 push-in) (2+2)
  • Rated operating voltage (Ue): (IEC) 500V|(UL) 600V|(Ex e II) 350V
  • Rated impulse voltage (Uimp): (IEC) 6kV
  • Connection type: Push-in CAGE CLAMP spring connections
  • Cross-section: for 0.14mm2...1.5mm2 fine stranded or solid conductors|for 0.14mm2...0.75mm2 fine stranded conductors with insulated ferrule|for 0.5mm2...0.75mm2 fine stranded conductors with ferrule; push-in termination|for 0.5mm2...1.5mm2 solid conductors; push-in termination|for #24AWG...#16AWG fine stranded or solid conductors|for #24AWG...#18AWG fine stranded conductors with insulated ferrule|for #20AWG...#18AWG fine stranded conductors with ferrule; push-in termination|for #20AWG...#16AWG solid conductors; push-in termination|1mm2 nominal cross-section
  • Mounting mode: DIN-35 rail (35 x 15 / 35 x 7.5)
  • Dimensions: H69.7mm x W3.5mm x D61.8mm
  • Net Width (mm): 3.5mm
  • Material: Polyamide (PA) 66
  • eClass code: 27-14-11-20
  • ETIM code: EC000897
  • Customs Tariff Number: 85369010000
  • GTIN code: 4055143267663
  • Order code / Manufacturer SKU: 2000-2239
  • Manufacturer product status: Commercialized
  • Equivalent to: 20002239
  • EAN code: 4055143267663
  • Compliant with standard(s): General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL 7962|- CSA - DEKRA Certification B.V. - C22.2 - certificate 2130762|- KEMA/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-125928|- UL - Underwriters Laboratories Inc. - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- ATEX-Attestation of Conformity - WAGO GmbH & Co. KG|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- Railway - WAGO GmbH & Co. KG - certificate Railway Ready|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for hazardous areas|- AEx - Underwriters Laboratories Inc. - UL 60079 - certificate E185892 (AEx eb IIC resp. Ex eb IIC)|- ATEX - Physikalisch Technische Bundesanstalt - EN 60079 - certificate PTB 11 ATEX 1041 U (II 2 G Ex eb IIC Gb bzw. I M 2 Ex eb I Mb)|- CCC - CNEX - GB/T 3836.3 - certificate 2020312313000182 (Ex eb IIC Gb / Ex eb I Mb)|- IECEx - Physikalisch Technische Bundesanstalt - IEC 60079 - certificate IECEx PTB 11.0093U (Ex e IIC Gb or Ex e I Mb)|RoHS compliant|material group I|V-0 flammability rating
  • Location of origin: China
  • Marking: "N"
  • Level 1 category: Electrical components
  • Level 2 category: Terminal blocks
  • Product title: Neutral-through terminal block - 2-decks/levels (double-deck) - WAGO (TOPJOB S series)

Commercial data

  • Country of origin: CN
  • Customs tariff number: 85369010000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-20
  • eCl@ss 9.0: 27-14-11-20
  • ETIM 8.0: EC000897
  • ETIM 9.0: EC000897
  • GTIN: 4055143267663
  • Packaging type: box
  • Product Group: 22 (TOPJOB S)
  • PU (SPU): 50 pcs

Connection data

  • Clamping units: 4
  • Connection 1 - Actuation type: Operating tool
  • Connection 1 - Connectable conductor materials: Copper
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.14 … 1.5 mm² / 24 … 16 AWG
  • Connection 1 - Fine-stranded conductor; with ferrule; push-in termination: 0.5 … 0.75 mm² / 20 … 18 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.14 … 0.75 mm² / 24 … 18 AWG
  • Connection 1 - Nominal cross-section: 1 mm²
  • Connection 1 - Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 - Solid conductor: 0.14 … 1.5 mm² / 24 … 16 AWG
  • Connection 1 - Solid conductor; push-in termination: 0.5 … 1.5 mm² / 20 … 16 AWG
  • Connection 1 - Strip length: 9 … 11 mm / 0.35 … 0.43 inches
  • Connection 1 - Wiring direction: Front-entry wiring
  • Number of jumper slots: 3
  • Number of levels: 2
  • Total number of potentials: 1

Electrical data

  • Ex information - Rated current (Ex e II): 13A
  • Ex information - Rated current (Ex e II) with jumper: 12A
  • Ex information - Rated voltage EN (Ex e II): 350V
  • Ex information - Ratings per: ATEX: PTB 11 ATEX 1041 U / IECEx: PTB 11.0093U (Ex eb IIC Gb)
  • Ex information - Reference hazardous areas: See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
  • Power Loss - Power loss, per pole (potential): 0.434W
  • Power Loss - Rated current IN for specified power loss: 13.5A
  • Power Loss - Resistance value for specified, current-dependent power loss: 0.002Ω
  • Ratings per CSA - Approvals per: CSA 22.2 No 158
  • Ratings per CSA - Rated current CSA (Use Group B): 10A
  • Ratings per CSA - Rated current CSA (Use Group C): 10A
  • Ratings per CSA - Rated voltage CSA (Use Group B): 600V
  • Ratings per CSA - Rated voltage CSA (Use Group C): 600V
  • Ratings per IEC/EN - Current at conductor cross-section (max.) mm²: 16A
  • Ratings per IEC/EN - Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • Ratings per IEC/EN - Nominal voltage (III/3): 500V
  • Ratings per IEC/EN - Rated current: 13.5A
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 6kV
  • Ratings per IEC/EN - Ratings per: IEC/EN 60947-7-1
  • Ratings per UL - Approvals per: UL 1059
  • Ratings per UL - Rated current UL (Use Group B): 15A
  • Ratings per UL - Rated current UL (Use Group C): 15A
  • Ratings per UL - Rated voltage UL (Use Group B): 300V
  • Ratings per UL - Rated voltage UL (Use Group C): 300V

Environmental Product Compliance

  • RoHS Compliance Status: Compliant,No Exemption

Environmental requirements

  • Continuous operating temperature: -60 … +105 °C
  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
  • Processing temperature: -35 … +85 °C

Material data

Mechanical data

  • Marking level: Center/side marking
  • Mounting type: DIN-35 rail
  • Potential marking: N

Physical data

  • Depth from upper-edge of DIN-rail: 61.8 mm / 2.433 inches
  • Height: 69.7 mm / 2.744 inches
  • Width: 3.5 mm / 0.138 inches