{"title":"WAGO WINSTA Installation System","description":null,"products":[{"product_id":"wago-890-733","title":"Wago - 890-733","description":"\u003cp\u003eWAGO component - equivalent to 890733\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233549\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-733\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890733\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233549\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 3-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE L|Mechanical data - Potential marking --N PE L|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.179MJ|Material data - Weight -- 6.9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233549|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233549\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.179MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N ⏚  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  ⏚  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539656196233,"sku":"890-733","price":2.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000c0000ba4c000200b6_de_6ffef192-af99-4b43-b0f9-98ab7e2c7b8c.jpg?v=1786983629"},{"product_id":"wago-890-713","title":"Wago - 890-713","description":"\u003cp\u003eWAGO component - equivalent to 890713\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233464\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-713\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890713\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233464\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 3-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE L|Mechanical data - Potential marking --N PE L|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.181MJ|Material data - Weight -- 5.5g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233464|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233464\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.181MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N ⏚  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  ⏚  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539656392841,"sku":"8900713","price":2.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000030002a606000100b6_de_23d2d33e-9e49-40df-81b7-66a68c476d01.jpg?v=1786986459"},{"product_id":"wago-890-752","title":"Wago - 890-752","description":"\u003cp\u003eWAGO component - equivalent to 890752\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143428132\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-752\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890752\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143428132\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 2-pole; Cod. B; 1.5mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 2 1|Mechanical data - Potential marking -- 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.116MJ|Material data - Weight -- 4.3g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143428132|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143428132\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.116MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539669926025,"sku":"60292734","price":2.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000130000729d000100b6_de_2e8a0c8b-c933-4623-a43c-1a4711f7d893.jpg?v=1786989524"},{"product_id":"wago-770-743","title":"Wago - 770-743","description":"\u003cp\u003eWAGO component - equivalent to 770743\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918252676\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-743\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770743\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918252676\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. B; 4mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 1 2 3|Mechanical data - Potential marking -- 1 2 3|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.232MJ|Material data - Weight -- 12g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918252676|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918252676\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.232MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539669991561,"sku":"51110261","price":3.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001200039be4000100b6_de_bc7912be-0714-43a1-ad0e-822e56a2fa40.jpg?v=1786984918"},{"product_id":"wago-890-792","title":"Wago - 890-792","description":"\u003cp\u003eWAGO component - equivalent to 890792\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143428101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-792\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890792\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143428101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 2-pole; Cod. B; 1.5mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 2 1|Mechanical data - Potential marking -- 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.116MJ|Material data - Weight -- 4.3g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143428101|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143428101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.116MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539674906761,"sku":"60292735","price":2.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300006fdc000100b6_de_ad2da118-6c46-4282-9296-01aff366d895.jpg?v=1786984722"},{"product_id":"wago-890-712","title":"Wago - 890-712","description":"\u003cp\u003eWAGO component - equivalent to 890712\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233457\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-712\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890712\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233457\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 2-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking --N L|Mechanical data - Potential marking --N L|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.159MJ|Material data - Weight -- 4.3g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233457|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233457\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.159MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539677954185,"sku":"890-712","price":2.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000030002a56c000100b6_de_9a630cae-a403-402f-81fe-ddafb731b130.jpg?v=1786983642"},{"product_id":"wago-890-772","title":"Wago - 890-772","description":"\u003cp\u003eWAGO component - equivalent to 890772\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143428194\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-772\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890772\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143428194\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 2-pole; Cod. B; 1.5mm2; light green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 2 1|Mechanical data - Potential marking -- 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- light green|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.116MJ|Material data - Weight -- 4.3g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143428194|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143428194\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.116MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539693813897,"sku":"60292740","price":2.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300006940000100b6_de_dcdff2ef-2f7a-43b9-92b1-4d3139b3b525.jpg?v=1786984540"},{"product_id":"wago-770-794","title":"Wago - 770-794","description":"\u003cp\u003eWAGO component - equivalent to 770794\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821445784\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-794\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770794\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821445784\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. B; 4mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 8|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 45.5mm \/ 1.791\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 4 3 2 1|Mechanical data - Potential marking -- 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.304MJ|Material data - Weight -- 14.7g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4050821445784|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821445784\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.304MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 14.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45.5 mm \/ 1.791 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539709968521,"sku":"7700794","price":4.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300001633000100b6_de_ff5f274a-6bd6-4053-9465-4db36284396d.jpg?v=1786990041"},{"product_id":"wago-770-723","title":"Wago - 770-723","description":"\u003cp\u003eWAGO component - equivalent to 770723\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918252638\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-723\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770723\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918252638\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. A; 4mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- L PE N|Mechanical data - Potential marking -- L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.237MJ|Material data - Weight -- 12.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918252638|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918252638\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.237MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539721142409,"sku":"51110257","price":3.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000080003a2a6000100b6_de_ef4cda7d-3b99-4098-8989-8edd49a446fb.jpg?v=1786989542"},{"product_id":"wago-770-2303","title":"Wago - 770-2303","description":"\u003cp\u003eWAGO component - equivalent to 7702303\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454435059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2303\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702303\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454435059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. P; 4mm2; red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- EDV (UPS)|Mechanical data - Coding -- P|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L PE N|Mechanical data - Potential marking -- L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- red|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.234MJ|Material data - Weight -- 12g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454435059|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454435059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.234MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e P\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e EDV (UPS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539725140105,"sku":"7702303","price":3.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6347955_de_0f1ecd0b-4a04-4e25-83e9-1b9045da88fa.jpg?v=1786985365"},{"product_id":"wago-890-2102","title":"Wago - 890-2102","description":"\u003cp\u003eWAGO component - equivalent to 8902102\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454548155\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-2102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 8902102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454548155\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 2-pole; Cod. I; 1.5mm2; blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- DALI; Lighting Management|Mechanical data - Coding -- I|Mechanical data - Variable coding -- No|Mechanical data - Marking -- + -|Mechanical data - Potential marking -- + -|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- blue|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.118MJ|Material data - Weight -- 4.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454548155|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454548155\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.118MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e +  -\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e +  -\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e DALI, Lighting Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539737591945,"sku":"8902102","price":2.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000080001a087000100b6_de_8d3976f9-0169-4d00-b16d-b3138616a7aa.jpg?v=1786986167"},{"product_id":"wago-770-2353","title":"Wago - 770-2353","description":"\u003cp\u003eWAGO component - equivalent to 7702353\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918254069\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2353\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702353\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918254069\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 3-pole; Cod. R; 4mm2; orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- LON Bus|Mechanical data - Coding -- R|Mechanical data - Variable coding -- No|Mechanical data - Marking -- S LON LON|Mechanical data - Potential marking -- S LON LON|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- orange|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.254MJ|Material data - Weight -- 11.9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918254069|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918254069\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.254MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 11.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e S  LON  LON\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e S  LON  LON\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e LON Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539750240393,"sku":"51110400","price":3.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6347441_de_4c8d7a81-7e56-4da4-af78-7773309fb363.jpg?v=1786987549"},{"product_id":"wago-770-784","title":"Wago - 770-784","description":"\u003cp\u003eWAGO component - equivalent to 770784\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821446255\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-784\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770784\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821446255\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 4-pole; Cod. B; 4mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 8|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 45.5mm \/ 1.791\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 1 2 3 4|Mechanical data - Potential marking -- 1 2 3 4|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.301MJ|Material data - Weight -- 15.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4050821446255|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821446255\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.301MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3  4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3  4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45.5 mm \/ 1.791 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539792183433,"sku":"7700784","price":5.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300001981000100b6_de_fa1e43ac-84cf-4b46-a2d2-c8aa8962a9cc.jpg?v=1786985158"},{"product_id":"wago-770-2363","title":"Wago - 770-2363","description":"\u003cp\u003eWAGO component - equivalent to 7702363\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918252768\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2363\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702363\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918252768\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. S; 4mm2; brown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- Switching function|Mechanical data - Coding -- S|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1 2 L|Mechanical data - Potential marking -- 1 2 L|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- brown|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.232MJ|Material data - Weight -- 12g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918252768|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918252768\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e brown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.232MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Switching function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539804799113,"sku":"51110270","price":3.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/11427017_de_2fb8c8dc-eea3-4641-8218-1104a368039a.jpg?v=1786985393"},{"product_id":"wago-890-2105","title":"Wago - 890-2105","description":"\u003cp\u003eWAGO component - equivalent to 8902105\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454885304\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-2105\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 8902105\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454885304\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 5-pole; Cod. I; 1.5mm2; blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 5|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- DALI; Lighting Management|Mechanical data - Coding -- I|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE L - +|Mechanical data - Potential marking --N PE L - +|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- blue|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.261MJ|Material data - Weight -- 9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454885304|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454885304\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.261MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  ⏚  L  -  +\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  ⏚  L  -  +\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e DALI, Lighting Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539805945993,"sku":"8902105","price":6.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000b00037937000100b6_de_af6175f8-0054-49ba-a22a-10727f5f1544.jpg?v=1786990480"},{"product_id":"wago-890-714","title":"Wago - 890-714","description":"\u003cp\u003eWAGO component - equivalent to 890714\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233471\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-714\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890714\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233471\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1\/L' 2\/L PE N|Mechanical data - Potential marking -- 1\/L' 2\/L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.185MJ|Material data - Weight -- 8g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233471|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233471\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.185MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1\/L'  2\/L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1\/L'  2\/L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539832357001,"sku":"8900714","price":3.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000e00024134000100b6_de_61c5602a-92fd-4d44-8dae-f1d2b051d83c.jpg?v=1786985167"},{"product_id":"wago-890-2115","title":"Wago - 890-2115","description":"\u003cp\u003eWAGO component - equivalent to 8902115\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454885311\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-2115\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 8902115\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454885311\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. I; 1.5mm2; blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 5|Connection data - Total number of potentials -- 5|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- DALI; Lighting Management|Mechanical data - Coding -- I|Mechanical data - Variable coding -- No|Mechanical data - Marking -- + - L PE N|Mechanical data - Potential marking -- + - L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- blue|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.252MJ|Material data - Weight -- 8g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454885311|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454885311\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.252MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e +  -  L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e +  -  L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e DALI, Lighting Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539845136521,"sku":"8902115","price":5.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000b000378aa000100b6_de_8f077592-8af9-438c-8c10-9d98b6911c31.jpg?v=1786984774"},{"product_id":"wago-890-734","title":"Wago - 890-734","description":"\u003cp\u003eWAGO component - equivalent to 890734\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233556\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-734\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890734\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233556\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1\/L' 2\/L PE N|Mechanical data - Potential marking -- 1\/L' 2\/L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.177MJ|Material data - Weight -- 8.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233556|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233556\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.177MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1\/L'  2\/L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1\/L'  2\/L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539871580297,"sku":"890-734","price":3.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001b0001fa5d000100b6_de_bfbb890b-f3b3-491c-be10-e5bdf47232a4.jpg?v=1786983728"},{"product_id":"wago-770-755","title":"Wago - 770-755","description":"\u003cp\u003eWAGO component - equivalent to 770755\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143594356\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-755\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770755\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143594356\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. B; 4mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4- and 5-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 10|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 55.5mm \/ 2.185\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 5 4 3 2 1|Mechanical data - Potential marking -- 5 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.369MJ|Material data - Weight -- 18g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143594356|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143594356\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4- and 5-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.369MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 18g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 5  4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 5  4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 55.5 mm \/ 2.185 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539876823177,"sku":"60333677","price":5.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000120003c6ae000100b6_de_4b92db4a-c406-41a2-9245-f53017c4e3e5.jpg?v=1786984995"},{"product_id":"wago-770-2324","title":"Wago - 770-2324","description":"\u003cp\u003eWAGO component - equivalent to 7702324\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454299170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2324\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702324\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454299170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 4-pole; Cod. Q; 4mm2; green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 32A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 8|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 45.5mm \/ 1.791\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- for \"Clean Ground\" applications|Mechanical data - Coding -- Q|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE1 PE2 L|Mechanical data - Potential marking --N PE1 PE2 L|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- green|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.299MJ|Material data - Weight -- 15.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454299170|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454299170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.299MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e Q\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  PE1  PE2  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  PE1  PE2  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e for \"Clean Ground\" applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45.5 mm \/ 1.791 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539918635145,"sku":"51175383","price":5.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001c0002d5b3000100b6_de_9e1e19e5-0ed9-412e-9e84-609700acf53c.jpg?v=1786986255"},{"product_id":"wago-890-793","title":"Wago - 890-793","description":"\u003cp\u003eWAGO component - equivalent to 890793\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143427777\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-793\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890793\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143427777\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 3-pole; Cod. B; 1.5mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 13A for 3-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 3 2 1|Mechanical data - Potential marking -- 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.154MJ|Material data - Weight -- 5.5g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143427777|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143427777\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 13 A for 3-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.154MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539942588553,"sku":"60292748","price":3.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300007183000100b6_de_1fab8575-d79d-4648-bf44-01b6bc50d279.jpg?v=1786989624"},{"product_id":"wago-770-2343","title":"Wago - 770-2343","description":"\u003cp\u003eWAGO component - equivalent to 7702343\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918252751\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2343\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702343\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918252751\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. R; 4mm2; orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- LON Bus|Mechanical data - Coding -- R|Mechanical data - Variable coding -- No|Mechanical data - Marking -- LON LON S|Mechanical data - Potential marking -- LON LON S|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- orange|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.235MJ|Material data - Weight -- 12.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918252751|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918252751\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.235MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e LON  LON  S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e LON  LON  S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e LON Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539944128649,"sku":"51110269","price":3.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/11427015_de_ecde25ee-9635-4dea-8739-b216d43117c7.jpg?v=1786987638"},{"product_id":"wago-890-735","title":"Wago - 890-735","description":"\u003cp\u003eWAGO component - equivalent to 890735\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233563\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-735\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890735\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233563\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 13A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 5|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 3 2 1 PE N|Mechanical data - Potential marking -- 3 2 1 PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.252MJ|Material data - Weight -- 8.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233563|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233563\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 13A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.252MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 3  2  1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 3  2  1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539956646025,"sku":"8900735","price":4.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000f00003489000200b6_de_829f580a-abbf-43a0-be8a-d9a3ee99ea0d.jpg?v=1786985028"},{"product_id":"wago-770-735","title":"Wago - 770-735","description":"\u003cp\u003eWAGO component - equivalent to 770735\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143375917\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-735\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770735\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143375917\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. A; 4mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 10|Connection data - Total number of potentials -- 5|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 55.5mm \/ 2.185\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- L3 L2 L1 PE N|Mechanical data - Potential marking -- L3 L2 L1 PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.403MJ|Material data - Weight -- 19.2g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143375917|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143375917\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.403MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 19.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L3  L2  L1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L3  L2  L1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 55.5 mm \/ 2.185 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539993444489,"sku":"60279727","price":4.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6347866_de_beace069-4a94-428f-92ae-456632daa7de.jpg?v=1786984420"},{"product_id":"wago-890-704","title":"Wago - 890-704","description":"\u003cp\u003eWAGO component - equivalent to 890704\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233426\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-704\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890704\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233426\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 4-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE 2\/L 1\/L'|Mechanical data - Potential marking --N PE 2\/L 1\/L'|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.184MJ|Material data - Weight -- 7.3g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233426|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233426\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.184MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 7.3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  ⏚  2\/L  1\/L'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  ⏚  2\/L  1\/L'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539997409417,"sku":"8900704","price":4.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000e00024251000100b6_de_27b35f4b-0ed2-4d84-8125-73bcc478feb5.jpg?v=1786985214"},{"product_id":"wago-890-744","title":"Wago - 890-744","description":"\u003cp\u003eWAGO component - equivalent to 890744\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143427623\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-744\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890744\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143427623\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 4-pole; Cod. B; 1.5mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 13A for 3-pole load \/ 10A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1 2 3 4|Mechanical data - Potential marking -- 1 2 3 4|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.184MJ|Material data - Weight -- 7.4g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143427623|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143427623\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 13 A for 3-pole load\u003cbr\u003e10 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.184MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 7.4g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3  4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3  4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540008779913,"sku":"60288431","price":5.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300024a58000100b6_de_24f3d98f-a770-4984-82ab-e4a7b73b8893.jpg?v=1786984426"},{"product_id":"wago-770-783","title":"Wago - 770-783","description":"\u003cp\u003eWAGO component - equivalent to 770783\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821458203\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821458203\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. B; 4mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 1 2 3|Mechanical data - Potential marking -- 1 2 3|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.234MJ|Material data - Weight -- 12.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4050821458203|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821458203\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.234MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540022476937,"sku":"770-783","price":3.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000120003efb9000100b6_de_a9440e37-3240-4fd9-8205-955a66d39ec0.jpg?v=1786984079"},{"product_id":"wago-770-795","title":"Wago - 770-795","description":"\u003cp\u003eWAGO component - equivalent to 770795\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143594783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-795\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770795\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143594783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. B; 4mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4- and 5-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 10|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 55.5mm \/ 2.185\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 5 4 3 2 1|Mechanical data - Potential marking -- 5 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.395MJ|Material data - Weight -- 18.9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143594783|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143594783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4- and 5-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.395MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 18.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 5  4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 5  4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 55.5 mm \/ 2.185 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540050821257,"sku":"60333688","price":5.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000130000148c000100b6_de_3e17d27b-aa8b-4434-b58f-6dfb630f53b7.jpg?v=1786989662"},{"product_id":"wago-890-715","title":"Wago - 890-715","description":"\u003cp\u003eWAGO component - equivalent to 890715\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233488\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-715\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890715\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233488\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 13A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 5|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 3 2 1 PE N|Mechanical data - Potential marking -- 3 2 1 PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.252MJ|Material data - Weight -- 8g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (25) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233488|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233488\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (25) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 13A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.252MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 3  2  1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 3  2  1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540065173641,"sku":"8900715","price":4.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000b00037ade000100b6_de_5b509874-1e43-40ff-8ffd-9a0d21bc7f44.jpg?v=1786989860"},{"product_id":"wago-890-724","title":"Wago - 890-724","description":"\u003cp\u003eWAGO component - equivalent to 890724\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233518\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-724\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890724\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233518\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 4-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE 2\/L 1\/L'|Mechanical data - Potential marking --N PE 2\/L 1\/L'|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.184MJ|Material data - Weight -- 10.7g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233518|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233518\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.184MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 10.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  ⏚  2\/L  1\/L'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  ⏚  2\/L  1\/L'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540066451593,"sku":"8900724","price":4.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6281898_de_11770baa-dba6-408b-b300-d4ce3bf6b5b6.jpg?v=1786985496"},{"product_id":"wago-890-702","title":"Wago - 890-702","description":"\u003cp\u003eWAGO component - equivalent to 890702\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233396\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-702\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890702\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233396\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 2-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L N|Mechanical data - Potential marking -- L N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.16MJ|Material data - Weight -- 4.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233396|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233396\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.16MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540077297801,"sku":"890-702","price":2.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000030002adc8000100b6_de_85b1f6c2-6bd5-46d2-b9df-924dac705742.jpg?v=1786984291"},{"product_id":"wago-890-2112","title":"Wago - 890-2112","description":"\u003cp\u003eWAGO component - equivalent to 8902112\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454548162\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-2112\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 8902112\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454548162\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 2-pole; Cod. I; 1.5mm2; blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- DALI; Lighting Management|Mechanical data - Coding -- I|Mechanical data - Variable coding -- No|Mechanical data - Marking -- - +|Mechanical data - Potential marking -- - +|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- blue|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.158MJ|Material data - Weight -- 5.2g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454548162|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454548162\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.158MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e -  +\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e -  +\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e DALI, Lighting Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540091912329,"sku":"8902112","price":2.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000800019e23000100b6_de_278f3ed5-c352-4396-885e-782bbb5d19f4.jpg?v=1786986667"},{"product_id":"wago-770-2105","title":"Wago - 770-2105","description":"\u003cp\u003eWAGO component - equivalent to 7702105\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143594806\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2105\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702105\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143594806\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 5-pole; Cod. I; 4mm2; blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 10|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 55.5mm \/ 2.185\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- DALI; Lighting Management|Mechanical data - Coding -- I|Mechanical data - Variable coding -- No|Mechanical data - Marking --N PE L DA- DA+|Mechanical data - Potential marking --N PE L DA- DA+|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- blue|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.423MJ|Material data - Weight -- 18.4g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143594806|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143594806\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.423MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 18.4g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  ⏚  L  DA-  DA+\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  ⏚  L  DA-  DA+\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e DALI, Lighting Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 55.5 mm \/ 2.185 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540094140553,"sku":"60333691","price":6.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/02000008000178ac000200b6_de_fa4536bf-f2f2-458b-8eb7-4dc80bb6fae1.jpg?v=1786985507"},{"product_id":"wago-770-744","title":"Wago - 770-744","description":"\u003cp\u003eWAGO component - equivalent to 770744\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918252683\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-744\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770744\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918252683\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 4-pole; Cod. B; 4mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 8|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 45.5mm \/ 1.791\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 1 2 3 4|Mechanical data - Potential marking -- 1 2 3 4|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.301MJ|Material data - Weight -- 15.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918252683|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918252683\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.301MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3  4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3  4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45.5 mm \/ 1.791 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540095516809,"sku":"51110262","price":5.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000120003cba3000100b6_de_e895098d-16af-40fe-a5fc-f947daef8954.jpg?v=1786986017"},{"product_id":"wago-890-723","title":"Wago - 890-723","description":"\u003cp\u003eWAGO component - equivalent to 890723\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233501\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-723\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890723\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233501\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L PE N|Mechanical data - Potential marking -- L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.221MJ|Material data - Weight -- 6.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233501|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233501\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.221MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540117340297,"sku":"890-723","price":3.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000d00029b23000200b6_de_14769d27-e6ed-400e-bf5d-ace439422221.jpg?v=1786983815"},{"product_id":"wago-770-2315","title":"Wago - 770-2315","description":"\u003cp\u003eWAGO component - equivalent to 7702315\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143375894\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-2315\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7702315\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143375894\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 5-pole; Cod. P; 4mm2; red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 10|Connection data - Total number of potentials -- 5|Connection data - PE function -- Preceding PE contact|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 55.5mm \/ 2.185\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- EDV (UPS)|Mechanical data - Coding -- P|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L3 L2 L1 PE N|Mechanical data - Potential marking -- L3 L2 L1 PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- red|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.388MJ|Material data - Weight -- 18.7g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143375894|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143375894\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePE function:\u003c\/strong\u003e Preceding PE contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.388MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 18.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e P\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L3  L2  L1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L3  L2  L1  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e EDV (UPS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 55.5 mm \/ 2.185 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540122321033,"sku":"60279725","price":5.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6347428_de_d40ebad9-2aa1-40c2-90a4-50e70976afed.jpg?v=1786986682"},{"product_id":"wago-890-722","title":"Wago - 890-722","description":"\u003cp\u003eWAGO component - equivalent to 890722\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233495\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-722\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890722\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233495\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 2-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L N|Mechanical data - Potential marking -- L N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.118MJ|Material data - Weight -- 4.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233495|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233495\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.118MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540132741257,"sku":"8900722","price":2.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6281895_de_7ca99e0f-bafe-4688-86b2-31d998347311.jpg?v=1786990391"},{"product_id":"wago-770-774","title":"Wago - 770-774","description":"\u003cp\u003eWAGO component - equivalent to 770774\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821458197\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-774\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770774\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821458197\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. B; 4mm2; light green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 8|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 45.5mm \/ 1.791\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 4 3 2 1|Mechanical data - Potential marking -- 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- light green|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.304MJ|Material data - Weight -- 14.7g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4050821458197|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821458197\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.304MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 14.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45.5 mm \/ 1.791 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540132806793,"sku":"7700774","price":4.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300001ccf000100b6_de_22c141d7-be06-42e9-801b-576f9288c4b5.jpg?v=1786985090"},{"product_id":"wago-770-753","title":"Wago - 770-753","description":"\u003cp\u003eWAGO component - equivalent to 770753\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918253994\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-753\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770753\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918253994\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 3-pole; Cod. B; 4mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 6|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 35.5mm \/ 1.398\"|Physical data - Height -- 17.5mm \/ 0.689\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 3 2 1|Mechanical data - Potential marking -- 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.267MJ|Material data - Weight -- 12.2g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918253994|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918253994\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.267MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.5 mm \/ 0.689 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35.5 mm \/ 1.398 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540133658761,"sku":"51110393","price":3.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001200039d8b000100b6_de_98c13438-feb8-40ba-99af-efba6aa3d258.jpg?v=1786989878"},{"product_id":"wago-890-743","title":"Wago - 890-743","description":"\u003cp\u003eWAGO component - equivalent to 890743\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143427838\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-743\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890743\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143427838\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. B; 1.5mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 13A for 3-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1 2 3|Mechanical data - Potential marking -- 1 2 3|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.178MJ|Material data - Weight -- 6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143427838|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143427838\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 13 A for 3-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.178MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540135788681,"sku":"60292755","price":3.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000f00007a9a000200b6_de_18e31b8b-36da-4916-bcfc-e69281257941.jpg?v=1786985524"},{"product_id":"wago-890-703","title":"Wago - 890-702","description":"\u003cp\u003eWAGO component - equivalent to 890702\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233396\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-702\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890702\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233396\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 2-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L N|Mechanical data - Potential marking -- L N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.16MJ|Material data - Weight -- 4.6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233396|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233396\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.16MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540160561289,"sku":"890-702","price":2.59,"currency_code":"USD","in_stock":true}]},{"product_id":"wago-890-705","title":"Wago - 890-703","description":"\u003cp\u003eWAGO component - equivalent to 890703\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233419\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-703\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890703\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233419\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. A; 1.5mm2; black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking -- L PE N|Mechanical data - Potential marking -- L PE N|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- black|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.221MJ|Material data - Weight -- 6.1g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233419|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233419\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.221MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e L  ⏚  N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540171243657,"sku":"8900703","price":3.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000030002ae61000100b6_de_18fabbfa-6d9e-4f2a-8d47-bc0c5dee8e4c.jpg?v=1786985695"},{"product_id":"wago-890-742","title":"Wago - 890-742","description":"\u003cp\u003eWAGO component - equivalent to 890742\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143428200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-742\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890742\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143428200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 2-pole; Cod. B; 1.5mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1 2|Mechanical data - Potential marking -- 1 2|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.116MJ|Material data - Weight -- 4.5g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143428200|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143428200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.116MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540171407497,"sku":"60292741","price":2.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300007444000100b6_de_84f186b7-f3a8-44e1-bf42-b71ef5ba49e3.jpg?v=1786984481"},{"product_id":"wago-770-754","title":"Wago - 770-754","description":"\u003cp\u003eWAGO component - equivalent to 770754\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918254007\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-754\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770754\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918254007\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. B; 4mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 8|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 45.5mm \/ 1.791\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 41.1mm \/ 1.618\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 4 3 2 1|Mechanical data - Potential marking -- 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.337MJ|Material data - Weight -- 15.9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 100 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4044918254007|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918254007\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 100 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.337MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 41.1 mm \/ 1.618 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45.5 mm \/ 1.791 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540174225545,"sku":"51110394","price":4.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000120003c855000100b6_de_ea9abd9c-6fb1-46cb-b4ed-c3c6162ef14f.jpg?v=1786985538"},{"product_id":"wago-770-785","title":"Wago - 770-785","description":"\u003cp\u003eWAGO component - equivalent to 770785\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143594400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 770-785\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 770785\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143594400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 5-pole; Cod. B; 4mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 25A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 25A for 3-pole load \/ 20A for 4- and 5-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 23A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 10|Connection data - Total number of potentials -- 5|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 4mm2 \/ 12 AWG|Connection data - Connection 1 - Solid conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 1.5...4mm2 \/ 16...12 AWG|Connection data - Connection 1 - Stranded conductor -- 0.5...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.5...4mm2 \/ 20...12 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...2.5mm2 \/ 20...14 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 5|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 10mm \/ 0.394\"|Physical data - Width -- 55.5mm \/ 2.185\"|Physical data - Height -- 18.5mm \/ 0.728\"|Physical data - Depth -- 37.5mm \/ 1.476\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- Yes|Mechanical data - Marking -- 1 2 3 4 5|Mechanical data - Potential marking -- 1 2 3 4 5|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; When mated IP2xC (These compact connectors are not designed for use in open; easily accessible areas!)|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.35MJ|Material data - Weight -- 18.7g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143594400|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143594400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 4 mm² \/ 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.5 … 4 mm² \/ 20 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 1.5 … 4 mm² \/ 16 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.5 … 2.5 mm² \/ 20 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 25 A for 3-pole load\u003cbr\u003e20 A for 4- and 5-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.35MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 18.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3  4  5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3  4  5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 37.5 mm \/ 1.476 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 18.5 mm \/ 0.728 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 10 mm \/ 0.394 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 55.5 mm \/ 2.185 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540201324681,"sku":"60333685","price":6.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/02000013000017da000100b6_de_4dc75711-5d44-4c0b-b131-ebc6aee2f633.jpg?v=1786986091"},{"product_id":"wago-890-754","title":"Wago - 890-754","description":"\u003cp\u003eWAGO component - equivalent to 890754\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143427678\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-754\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890754\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143427678\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. B; 1.5mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 13A for 3-pole load \/ 10A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 4 3 2 1|Mechanical data - Potential marking -- 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- gray|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.199MJ|Material data - Weight -- 6.9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143427678|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143427678\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 13 A for 3-pole load\u003cbr\u003e10 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.199MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540201783433,"sku":"60288459","price":4.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/02000013000248b1000100b6_de_e7e4b6f4-fd70-4a17-8194-f703a48d8606.jpg?v=1786984651"},{"product_id":"wago-890-732","title":"Wago - 890-732","description":"\u003cp\u003eWAGO component - equivalent to 890732\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454233532\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-732\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890732\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454233532\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 2-pole; Cod. A; 1.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 19.8mm \/ 0.78\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- General mains applications|Mechanical data - Coding --A|Mechanical data - Variable coding -- No|Mechanical data - Marking --N L|Mechanical data - Potential marking --N L|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- white|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.159MJ|Material data - Weight -- 5.2g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4045454233532|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454233532\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.159MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e N  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e N  L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e General mains applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 19.8 mm \/ 0.78 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540225441929,"sku":"8900732","price":2.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6281906_de_a591775c-3306-481c-a5e1-230e94f5c380.jpg?v=1786989509"},{"product_id":"wago-890-783","title":"Wago - 890-783","description":"\u003cp\u003eWAGO component - equivalent to 890783\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143427746\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890783\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143427746\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in socket; 3-pole; Cod. B; 1.5mm2; pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 250V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 13A for 3-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 14A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 3|Connection data - Total number of potentials -- 3|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 3|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 24.2mm \/ 0.953\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 1 2 3|Mechanical data - Potential marking -- 1 2 3|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP40|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- pink|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.044MJ|Material data - Weight -- 6g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143427746|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143427746\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 13 A for 3-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 14A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e pink\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.044MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 1  2  3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.2 mm \/ 0.953 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540389118089,"sku":"60292745","price":3.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001300006e35000100b6_de_f78d9d28-999c-4213-b989-92e439853159.jpg?v=1786989974"},{"product_id":"wago-890-774","title":"Wago - 890-774","description":"\u003cp\u003eWAGO component - equivalent to 890774\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143427968\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 890-774\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 890774\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143427968\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Snap-in plug; 4-pole; Cod. B; 1.5mm2; light green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The snap-in connectors must be relieved of tensile and transverse forces. \/A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit; so ensure an adequate fit before use. In addition; the punched edge should be on the inside for punched cutouts. \/ The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g.; due to a pre-locking position).|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 400V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 16A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 3) Overvoltage category III \/ Pollution degree 3|Electrical data - Ratings per IEC\/EN - Notes - Rated current (note) -- 13A for 3-pole load \/ 10A for 4-pole load|Electrical data - Ratings per UL 1977 - Note for the US market -- Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5A and voltages up to 600 V. For further information; please contact your local sales office.|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 12A|Electrical data - General information - Note on contact resistance -- approx. 1mΩ of contact resistance \/ approx. 0.25mΩ contact transition plug\/socket|Connection data - Clamping units -- 4|Connection data - Total number of potentials -- 4|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Operating tool \/ Push-in|Connection data - Connection 1 - Nominal cross-section -- 1.5mm2 \/ 16 AWG|Connection data - Connection 1 - Solid conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Solid conductor; push-in termination -- 0.75...1.5mm2 \/ 20...16 AWG|Connection data - Connection 1 - Stranded conductor -- 0.25...1mm2 \/ 22...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.25...1.5mm2 \/ 22...16 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...0.75mm2 \/ 22...20 AWG|Connection data - Connection 1 - Fine-stranded conductor; with ferrule; push-in termination -- 0.75mm2 \/ 20 AWG|Connection data - Connection 1 - Strip length -- 9mm \/ 0.35\"|Connection data - Connection 1 - Pole number -- 4|Connection data - Connection 1 - Conductor entry direction to mating direction -- 0°|Physical data - Pin spacing -- 4.4mm \/ 0.173\"|Physical data - Width -- 28.6mm \/ 1.126\"|Physical data - Height -- 16mm \/ 0.63\"|Physical data - Depth -- 39.85mm \/ 1.569\"|Mechanical data - Use -- Control technology|Mechanical data - Coding -- B|Mechanical data - Variable coding -- No|Mechanical data - Marking -- 4 3 2 1|Mechanical data - Potential marking -- 4 3 2 1|Mechanical data - Mating force of a plug-in connection -- approx. 20...70N (depending on pole number)|Mechanical data - Retention force of a plug-in connection -- Locked \u0026gt; 80N|Mechanical data - Unmating force of a plug-in connection -- Unlocked approx. 20...70N (depending on pole number)|Mechanical data - Number of mating cycles -- 200; without resistive load|Mechanical data - Housing sheet thickness -- 0.5...2mm \/ 0.02...0.079\"|Mechanical data - Mounting type -- Snap-in flange|Mechanical data - Protection type -- IP20; IP40 when mated|Plug-in connection - Contact type (pluggable connector) -- Male connector\/plug|Plug-in connection - Connector (connection type) -- for conductor|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Note on mismating protection -- All WINSTA components are 100% protected against mismating when \/ a.) plugging different numbers of poles \/ b.) plugging while rotated 180 \/ c.) plugging while laterally staggered \/ d.) plugging one pole|Plug-in connection - Locking lever -- yes|Plug-in connection - Locking of plug-in connection -- locking lever|Plug-in connection - Note on locking system -- All connectors for mounted installations (snap-in versions for lighting fixtures or devices; all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).|Material data - Color -- light green|Material data - Cover color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper or Copper alloy; surface-treated|Material data - Contact plating -- Tin|Material data - Fire load -- 0.184MJ|Material data - Weight -- 6.9g|Environmental requirements - Processing temperature -- -5...+40°C|Environmental requirements - Continuous operating temperature -- -35...+85°C|Environmental requirements - Note on continuous operating temperature -- Insulating parts for temperatures ≤ 105°C|Commercial data - Product Group -- 20 (Winsta)|Commercial data - eClass 10.0 -- 27-44-06-02|Commercial data - eClass 9.0 -- 27-44-06-02|Commercial data - ETIM 9.0 -- EC002566|Commercial data - ETIM 8.0 -- EC002566|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 (50) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143427968|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-06-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143427968\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 20 (Winsta)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 (50) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool|Push-in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor entry direction to mating direction:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with ferrule; push-in termination:\u003c\/strong\u003e 0.75 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm² \/ 22 … 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Nominal cross-section:\u003c\/strong\u003e 1.5 mm² \/ 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor; push-in termination:\u003c\/strong\u003e 0.75 … 1.5 mm² \/ 20 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Stranded conductor:\u003c\/strong\u003e 0.25 … 1 mm² \/ 22 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 9 mm \/ 0.35 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral information - Note on contact resistance:\u003c\/strong\u003e approx. 1 mΩ of contact resistance\u2029\u003cbr\u003eapprox. 0.25 mΩ contact transition plug\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 3) ≙ Overvoltage category III \/ Pollution degree 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN – Notes - Rated current (note):\u003c\/strong\u003e 13 A for 3-pole load\u003cbr\u003e10 A for 4-pole load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Note for the US market:\u003c\/strong\u003e Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 5 A and voltages up to 600 V. For further information, please contact your local sales office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -35 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on continuous operating temperature:\u003c\/strong\u003e Insulating parts for temperatures ≤ 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -5 … +40 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper or copper alloy; surface-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover color:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.184MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing sheet thickness:\u003c\/strong\u003e 0.5 … 2 mm \/ 0.02 … 0.079 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating force of a plug-in connection:\u003c\/strong\u003e approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e Snap-in flange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of mating cycles:\u003c\/strong\u003e 200, without resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential marking:\u003c\/strong\u003e 4  3  2  1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; IP40 when mated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention force of a plug-in connection:\u003c\/strong\u003e Locked: \u0026gt; 80 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnmating force of a plug-in connection:\u003c\/strong\u003e Unlocked: approx. 20 … 70 N (depending on pole number)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The snap-in connectors must be relieved of tensile and transverse forces.\u003cbr\u003eA surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.\u003cbr\u003eThe wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole markings|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 39.85 mm \/ 1.569 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 mm \/ 0.63 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 4.4 mm \/ 0.173 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 28.6 mm \/ 1.126 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Male connector\/plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking lever:\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e locking lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on locking system:\u003c\/strong\u003e All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug\/socket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on mismating protection:\u003c\/strong\u003e All  \u003ci\u003eWINSTA\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e components are 100% protected against mismating when:\u003cbr\u003ea.) plugging different numbers of poles\u003cbr\u003eb.) plugging while rotated 180 \u2029\u003cbr\u003ec.) plugging while laterally staggered\u003cbr\u003ed.) plugging one pole\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47540398489737,"sku":"60288460","price":4.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/6281935_de_ac207d6c-49b1-4036-a0af-18c69107ca82.jpg?v=1786985331"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/collections\/png_d92f93e8-0016-4ec2-8d2b-4820d8ffbfea.png?v=1784299779","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/collections\/wago-winsta.oembed","provider":"US Automation Controls","version":"1.0","type":"link"}